7800 Family User Instructions
19
5.5
5.5 Baud Rate and Parity Options
*Default Factory Settings
5.6 Diagnostic (DIAG) Mode
The Diagnostic (DIAG) Mode menu allows testing of specific areas of the scale’s
function and viewing of current configuration settings. Areas to test the scale’s function
are:
DISPLAY (DISP)
– Shows the version and revision of the software, followed by a
display segment test.
The databits and stop bits default values are 7 data bits and 1 stop bit. These are not
configurable.
Table 5.2 Baud Rate and Parity Options
Display
Baud
Parity
12 E
1200
Even
24 E
2400
Even
48 E
4800
Even
*96 E
9600
Even
19.2 E
19.2K
Even
12 o
1200
Odd
24 o
2400
Odd
48 o
4800
Odd
96 o
9600
Odd
19.2 o
19.2K
Odd
12 n
1200
None
48 n
4800
None
96 n
9600
None
19.2 n
19.2K
None
Quickly and easily gain access to the Diagnostic mode directly from the front panel
without opening the scale or setting switches as follows:
Press and hold the
TEST
key. The display will flash
78--
, the program version, and
then
_ _ _ _
. Now release the
TEST
key.
To exit the Diagnostic mode press the
ZERO
key until
DONE
is displayed, then press
the
TEST
key to return to normal weighing mode.
IMPORTANT
: Internal rocker switches will be ignored until you exit this special mode
or power reset the scale.