21
AVENTICS
| ST4-2P |
R412012414–BAL–001–AE
4
Servicedaten (I/O-Link) / Service data (I/O link) / Données de maintenance (lien E/S) /
Dati per l'assistenza (I/O link) / Datos de servicio (enlace E/S) / Servicedata (I/U-länk)
SPDU-Index
Index
Sub-
index
Meaning
Format/Bytes
Access
Example
Range
Remark
0x10
Manufacturer ID
visible string
R
AVENTICS GmbH
exactly 16 strings
0x12
Device ID
visible string
R
ST4-2P
ST4-2P
exactly 16 strings
0x15
Serial number
visible string
R
123
dez
1-2E
32
0x16
HW version number
visible string
R
1.00
0x17
SW version number
visible string/4 Byte
R
2.33
0x18
Application-specific
name
visible string/ max.
16 Byte
R/W
0x90
Teach parameter:
switching point 1
UINT8, 8 Byte
R
0 ...
1023
No arguments
0x91
Teach parameter:
switching point 2
UINT8, 8 Byte
R
0 ...
1023
No arguments
0x92
Tolerance step
UINT8, 3 Byte
R/W
1-5
0x28
Process data state
output 1 and output 2
UINT8, 1 Byte
R
00
01
10
11
Q1 and Q2 inactive
Q1 active
Q2 active
Q1 and Q2 active
0xE2
Hall signals channel
A and channel B
UINT8, 4 Byte
R
0 ...
1023
High Byte
Low Byte
SPDU System Command
Index
Subindex
Meaning
Format/Bytes
Access
Example
Range
Remark
0x02
Teach switching point 1
UINT8
W
AxA0
Teach command SP1
Teach switching point 2
0xA1
Teach command SP2
Lock global key
0xA3
Deactivates teach button
Unlock global key
0xA4
Activates teach button
SPDU-Index error codes
Index
Subindex
Index
Subindex
0x1000
Communication error
0x80xx
Device-specific error
0x5200
Buffer overflow
0x8000
No details
0x5600
Checksum error
0x8023
Access denied
0x5800
Illegal SPDU
0x8030
Parameter value out of range
Event data
Meaning
Mode
Type
Instance
Error code
Parameter changed
Once
Info
Application
0xFF10
Communication error
Once
Error
Unknown
0xFF10
Summary of Contents for ST4-2P
Page 23: ......