Technical Data
110
AVENTICS
| PROFINET-IO | R412015162–BDL–001–AE
9
Technical Data
9.1
Characteristics
9.2
Bus coupler
General
Protection class according to EN 60529/IEC 529
IP 65 when assembled
Ambient temperature
U
W
Operation
W
Storage
0°C to +50°C, without condensation
-20°C to +70°C
Electromagnetic compatibility
Interference emission
EN 61000-6-4
Interference immunity
EN 61000-6-2
Electrics
Operating voltage
W
Logic
– U
L
24 V DC (+20%/15%)
– I
L
100 mA
– Protection for the power supply
1.2 AF
W
Load U
Q1
, U
Q2
24 V DC (+20% to -10%)
1)
,
Protective extra-low voltage (SELV/PELV) according
to EC 364-4-41,
Residual ripple 0.5%
1)
Deviation depends on the connected valves
– Protection for the power supply
2x 2.0 AF
Cable length for power supply
Max. 20 m
Maximum current in the 0 V line
4 A
Internal voltage drop
0.6 V
Max. output current per valve output
63 mA
Number of outputs
Max. 32
Number of output bytes
Fixed 4 byte output and 0 byte input
Run-up time
Approx. 1.2 s