Assembling the ED12
AVENTICS
| ED12 | R414002587–BDL–001–AB
49
Eng
lish
6.4
Screwing the ED12 onto the base plate
O
Insert both of the M6 x 70 screws as shown in Fig. 4 on page 46
in the four holes and tighten.
Tightening torque: 6 Nm
6.5
Connecting the supply voltage and set point
To operate the ED12, you must supply the device with compressed
air, connect the 24 V DC supply voltage, and control the device with
a set point.
The actual value (–) and set point (–) are always connected
with 0 V in all devices.
O
Observe the following tables that list the plug assignments for
the three different series with integrated
XPC
plug, M12;
integrated
X1S
plug, M12; and integrated
X2M
socket, M12, as
well as the rectangular plug, form A in accordance with DIN EN
175301-803.
00125293
5
1
2
3
4
Table 7:
ED12 with integrated
XPC
plug, M12
Integrated XPC plug, M12, male, 5-pin
Pin 1
24 V DC
Pin 2
Set point (+): current 0/4 to 20 mA
Pin 3
0 V
Pin 4
Actual value (+): current 0/4 to 20 mA
Pin 5
Functional grounding (FE)
00125293
5
1
2
3
4
Table 8:
ED12 with integrated
X1S
plug, M12,
Integrated X1S plug, M12, male, 5-pin
Pin 1
24 V DC
Pin 2
Not assigned
Pin 3
0 V
Pin 4
Not assigned
Pin 5
Functional grounding (FE)