Device description
44
AVENTICS
| ED12 | R414002587–BDL–001–AB
5.2
ED12 with two M12 plugs
Abb. 2: ED12 with integrated
X1S
plug and integrated
X2M
socket, M12
This ED12 model is available in the following variants
:
1
Equalization port cap
2
Housing ventilation port
3
Valve solenoids
4
Exhaust air connection
5
Inlet connection
6
Coded hole
7
Outlet connection
8
M6x70 screws (DIN EN ISO 4762,
formerly DIN 912)
9
Base plate seal
10
Housing seal
11
Housing cover mounting screws
13
Integrated
X1S
plug, M12
14
Integrated
X2M
socket, M12
Table 5:
ED12 with integrated
X1S
plug and integrated
X2M
socket,
M12
Order number
Outlet pressure
Set point
Actual value
R414001728
0 to 10 bar
0 to 20 mA
0 to 20 mA
R414001729
0 to 10 bar
4 to 20 mA
4 to 20 mA
R414001730
0 to 10 bar
0 to 10 V
10 V constant
1)
1)
To supply a set point potentiometer
R414001731
0 to 10 bar
0 to 10 V
0 to 10 V
13
11
10
14
1
2
11
5
6
4
8
9
3
3
7
00000000