![Avaya S8700 Series Maintenance Manual Download Page 889](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102889.webp)
ASAI-RES/E-DIG-RES (TN800 reserve slot)
Issue 1 May 2002
8-167
555-233-143
ASAI-RES/E-DIG-RES (TN800 reserve
slot)
There are no tests associated with these MOs. Both the test board and busyout
board commands abort when either is attempted on a reserved slot. An error
message indicates the slot is associated with the circuit pack that the TN800 is
emulating, but the requested operation is not valid.
The TN800 MAPD (Multi-Application Platform for DEFINITY) circuit pack
connects to the switch through a single slot in the backplane. The number of slots
occupied by the MAPD pack is supplied by the board when inserted. The TN800
in R5EM is three slots wide. The TN800 requires 2 reserve slots to its left. The
reserve (blank) slots are to left of the functional slot and are place holders on the
switch, and do not have any interaction with the switch.
Each instance of these MOs represents a reserve slot associated with respective
circuit pack mode in which the MAPD is working.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
Full Name of MO
ASAI-RES
NONE
NONE
TN800 ASAI reserve slot
E-DIG-RES
NONE
NONE
TN800 DIG reserve slot
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...