Maintenance-Object Repair Procedures
555-233-143
8-34
Issue 1 May 2002
ADX16A-PT (AUDIX Analog
Line/Control Link)
!
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow the
instructions on the TN566/TN2169 faceplate:
■
Remove EMBEDDED AUDIX circuit packs
■
Cycle power to a carrier containing EMBEDDED AUDIX circuit packs
■
Remove power to a carrier containing EMBEDDED AUDIX circuit packs
The ADX16A-PT MO represents a port on a TN566/TN2169 EMBEDDED AUDIX
circuit pack that is operating in control-link (CL) mode. For circuit-pack-level
problems (ADX16A-BD or ANL-16-BD), see
. For port-level problems with AUDIX operating in
digital-port mode, see:
■
‘‘ADX8D-PT (AUDIX Digital Port)’’ on page 8-16
■
‘‘ADX16D-P (16-Port AUDIX Digital Port)’’ on page 8-26
The tests described in this section apply only to switch-side maintenance that
tests a circuit pack’s components related to the TDM-bus interface. The AUDIX
system has an extensive maintenance strategy that is described in EMBEDDED
AUDIX System Maintenance, 585-300-110.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction
board (MFB) and the TN2169 Alarm board (ALB). Because of its size this
combination occupies 5 slots, but only 1 slot is functional as far as the switch is
concerned. The other 4 slots are seen by the switch as “AUDIX-reserved” slots.
In CL mode the TN566 pack supports up to 16 voice ports. When a call to a
station with an AUDIX login is not answered, AUDIX answers the call using one of
the available voice ports.
Unlike other AUDIX systems, EMBEDDED AUDIX is not an adjunct.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial Command to
Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21). pp is the 2-digit port number
(01, 02,...).
Full Name of MO
ADXCL-PT or
ADX16A-PT
MINOR
test port UUCSSpp l
AUDIX Analog Line/ Control Link
ADXCL-PT or
ADX16A-PT
WARNING
test port UUCSSpp sh
AUDIX Analog Line/ Control Link
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...