release commands
Issue 1 May 2002
7-247
555-233-143
release commands
release board UUCSS
release maintenance-name [address]
Release commands release specified maintenance objects from the maintenance
busyout state and puts them back into service, assuming the health of the
component(s) permits. Hardware tests specific to the maintenance object are
performed to verify that it is functioning.
For each maintenance object, the release command is entered in the same
fashion as the associated busyout command, except that the word release is
entered instead of busyout. See the description of the related busyout command
for details of command syntax.
If a release command is entered for an object that is not busied out, the command
will abort. Some release commands trigger recovery actions by the system, such
as the refresh of a standby PNC. See the description of the related busyout
command for details of command execution and interactions.
Parameters
Input parameters consist of specifying the location, if required, of the given
maintenance object. Use the same format as that used for the related busyout
command.
Examples
release board 01c11
release data-module 310
release Tone-Clock 2a
release ds1-fac 02e01a
release fiber-link 13
release port UUCSSpp
release station extension
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...