![Avaya S8700 Series Maintenance Manual Download Page 2425](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022425.webp)
USB1 (Modem Testing)
Issue 1 May 2002
8-1703
555-233-143
USB1 (Modem Testing)
USB1 Modem Testing
This MO provides periodic and on-demand testing. The periodic test runs the
“handshake” test every 15 minutes. The on-demand tests include the
“handshake”, “offhook”, and “reset_usb” tests.
Alarm Log Entries
Notes:
a. Event ID # 1 Handshake Test failed — With three consecutive failures of
either the periodic or on-demand test, the following Minor alarm is logged:
#1,ACT,USB1,A,1,MIN,USB Modem handshake test failed
MO’s Name (in
Alarm Log)
Alarm Level
Initial Linux Command
to Run
1
1.
Usage: testmodem [-s] | [-l] | [-t arg] | [-?]
no argument Performs “short” test.
-s Short test, performs handshake and
offhook
this is also the default option.
-l Performs “short” tests.
-t arg Specific test to perform. Possible
values for arg are: reset_usb |
handshake | offhook |
-? Usage (this).
Full Name of MO
USB1
MAJOR
testmodem
USB Port Modem Testing
USB1
MINOR
testmodem
USB Port Modem Testing
USB1
WARNING
testmodem
USB Port Modem Testing
Table 8-660.
USB1 Alarm Log Entries
EVENT
ID#
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Linux Test to Clear
Value
1 (a)
Handshake test
MINOR
ON
testdupboard
2 (b)
Modem Offhook test
MAJOR
ON
testdupboard
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...