Additional Maintenance Procedures
555-233-143
5-42
Issue 1 May 2002
Screen 5-2.
Summary Report Screen
Output Fields—ATMS Summary Report
Trk Grp Num
Results for each trunk group are listed by trunk-group number. Only
outgoing or 2-way analog trunks are listed.
Num Of Trks
The number of members in the trunk group.
Last Test Date
The date of the oldest measurement in the trunk group.
Last Test Time
The time of the oldest measurement in the trunk group.
Trunks Passed
Transm Test
The number of trunks that have passed the trunk transmission tests.
Trunks Failed
Marginal Threshld
The number of trunks that performed outside the marginal threshold, but
not the unacceptable threshold, as defined on the Trunk Group form.
Trunks Failed
Unaccept Threshld
The number of trunks that performed outside the unacceptable threshold,
as defined on the Trunk Group form.
Trks In-Use
The number of trunks that were in use at the time of testing. Abort codes
for trunk-in-use are 1000 and 1004.
Trks Not Test
The number of trunks that were not tested due to error conditions other
than trunk-in-use. Abort codes are given in the detailed report.
Busied Out Trunks
The number of trunks that were busied out in response to test failures.
These may be caused by hardware problems, incorrect threshold values,
and so on.
ATMS MEASUREMENT SUMMARY REPORT
Trunks Trunks Trunks
trk Num Last Last Passed Failed Failed Trks Trks Busied
Grp of Test Test Transm Marginal Unaccept In- Not Out
Num Trks Date Time Test Threshld Threshld Use Test Trunks
1 10 10/04/91 15:15 10 0 0 0 0 0
10 10 10/04/91 15:40 10 0 0 0 0 0
20 5 10/04/91 16:00 5 0 0 0 0 0
30 30 0 0 0 30 0
40 20 10/04/91 16:15 20 0 0 0 0 0
50 10 10/04/91 16:40 10 0 0 0 0 0
60 3 10/04/91 16:55 0 0 0 0 0 3
78 10 10/04/91 17:05 8 0 0 1 0 1
83 15 10.04/91 17:20 15 0 0 0 0 0
105 100 10/04/91 17:40 100 0 0 0 0 0
125 2 10/04/91 19:30 0 0 0 0 0 2
350 10 10/04/91 19:40 10 0 0 0 0 0
500 55 10/04/91 19:55 55 0 0 0 0 0
650 1 10/04/91 21:00 1 0 0 0 0 0
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...