![Avaya S8700 Series Maintenance Manual Download Page 1803](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021803.webp)
MEDPROPT (TN802/TN2302 MED PRO DSP PORT)
Issue 1 May 2002
8-1081
555-233-143
MEDPROPT (TN802/TN2302 MED
PRO DSP PORT)
The MEDPROPT MO monitors the health of the MEDPRO digital signal
processors (DSPs).
The TN802B/TN2302 MAP-D (Multi-Application Platform for DEFINITY) Media
Processor circuit pack provides the audio bearer channels for H.323 voice over IP
calls. One TN802B/TN2302 circuit pack has one MEDPROPT media processing
resource. Based on system administration of audio codecs, a MEDPROPT can
handle either 31 or 22 simultaneous channels of H.323 audio processing. If the
ip-parameters form specifies only G.711 mu-law or G.711 a-law as the audio
codecs, the MEDPROPT can service 31 channels. If any other codec type
(G.723-5.3K, G.723-6.3K, or G.729) is administered, the MEDPROPT can only
service 22 channels.
The MEDPROPT is physically made up of 11 individual DSPs, but is treated
logically as one port. If individual DSPs on the TN802B/TN2302 MAPD fail, the
MEDPROPT remains in-service at lower capacity.
The MEDPROPT is a shared service circuit. It is shared between H.323 trunk
channels and H.323 stations. An idle channel is allocated to an H.323
trunk/station on a call-by-call basis.
Error Log Entries and Test to Clear Values
MO’s Name
(in Alarm Log)
Alarm
Level
Initial SAT Command to
Run
Full Name of MO
MEDPROPT
MINOR
WARNING
test port UUCSS | PCSS
[short/long] [repeat#] |
[clear]
TN802/TN2302
MEDPRO DSP PORT
Table 8-442.
MEDPROPT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
Any
test board UUCCSS
1 (a)
ANY
DSP Capacity test (#1382)
ON
test board UUCCSS l r5
18 (b)
0
busyout port UUCSS
WARNING
OFF
release port UUCCSS
258 (c)
ANY
DSP Capacity test (#1382)
WARNING
ON
test board UUCCSS l r5
513 (d)
DSP Capacity test (#1382)
MINOR
ON
test port UUCCSSpp
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...