Maintenance-Object Repair Procedures
555-233-143
8-890
Issue 1 May 2002
H323-SGRP (323 Signaling Group)
The MO H.323 Signaling Group (H323-SGRP) supports a signaling channel (D
channel) for H.323 Trunk connections. The MedPro TN802 circuit pack provides
audio connectivity, working in concert with a C-LAN (TN799DP) circuit pack that
provides control signaling to support an H.323 connection.
The H.323 signaling group (H323-SGRP) is a Signaling channel that physically
resides on a C-LAN port (socket) and the IP network. Unlike ISDN D-channels,
the H.323 channel may actually come up and down on a call by call basis. The
H.323 channel is actually a TCP/IP signaling channel. Layers 1 and 2 of this
signaling channel are monitored by IP PING testing.
Error Log Entries and Test to Clear Values
1
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
MO’s Name (in
Alarm Log)
Alarm Level
Initial SAT Command to
Run
1
1.
grp# is the signaling group number (1–166); the test sequence can be either short or long.
Full Name of MO
H323-SGRP
MINOR
test sig-group grp#
H323 Signaling Group
H323-SGRP
WARNING
test sig-group grp#
H323 Signaling Group
Table 8-340.
H323-SGRP Signaling Group Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
0
Any
Any
test sig-group grp#
1 (a)
Any
Ethernet Port Status test
(#1386)
MINOR
OFF
test sig-group grp#
257 (b)
Any
H.323 SGRP PING test
(#1387)
MINOR
OFF
test sig-group grp#
513 (c)
Any
H.323 SGRP PING test
(#1387)
WARNING
OFF
test sig-group grp#
770 (d)
Any
WARNING
OFF
1025 (e)
Any
MEDPRO Status test (#1392)
MINOR
OFF
test sig-group grp#
1281 (f)
Any
MEDPRO Status test (#1392)
MINOR
OFF
1794 (g)
MEDPRO Status test (#1392)
MINOR
OFF
test sig-group grp#
2049 (h)
Keep Alive Failure
MINOR
OFF
test sig-group grp#
2305 (i)
Gateway Unregistered
MINOR
OFF
test sig-group grp#
Continued on next page
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...