![Avaya S8700 Series Maintenance Manual Download Page 154](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102154.webp)
Alarms, Errors, and Troubleshooting
555-233-143
4-80
Issue 1 May 2002
Troubleshooting the Outgoing
ISDN-Testcall Command
If the
TestCall BCC
field appears on the Trunk Group Administration form,
make sure the
TestCall BCC
field indicates the correct BCC for the service
provisioned on the ISDN-PRI trunk. The
TestCall BCC
values are defined as
follows:
If the ISDN-PRI trunk is of type
cbc
make sure the
TestCall Service
field on
the Trunk Group Administration form indicates the correct service so that a
network facility message can be sent across the ISDN-PRI network.
If the outgoing ISDN-PRI test call keeps aborting, make sure that the far-end
device can handle DCP Mode 0 or DCP Mode 1.
NOTE:
Before attempting to make an ISDN-PRI test call to the public network (that
is, the network is the far end), make sure that test call service is provisioned
by the network. The user must subscribe to Test Type 108 service and have
the correct far-end test call number administered on the Trunk Group form
for the call to be allowed.
0
Voice
1
Digital Communications Protocol Mode 1
2
Mode 2 Asynchronous
3
Mode 3 Circuit
4
Digital Communications Protocol Mode 0
(usually the default).
Summary of Contents for S8700 Series
Page 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Page 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Page 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Page 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Page 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Page 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...