AUDIX-PT (AUDIX Port)
The AUDIX-PT MO represents a port on a TN566/TN2169 EMBEDDED AUDIX
circuit pack operating in digital-port (DP) mode. For circuit-pack-level problems
(AUDIX-BD), see
‘‘XXX-BD (Common Port Circuit Pack)’’ on page 8-1872
The maintenance strategy for ports on the TN566 operating in control-link mode is
described in ADX16A-PT.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21).
pp is the 2-digit port number (01, 02,...).
Full Name of MO
AUDIX-PT
MINOR
test port UUCSSpp l
AUDIX port
AUDIX-PT
WARNING
test port UUCSSpp sh
AUDIX port