Final replacement tasks
03-602953 Issue 1 June 2008
31
Save translations
To synchronize the main server’s translations with the LSP:
1. Log in to the main server’s SAT interface.
2. At the SAT prompt type
save translation lsp
and press
Enter
.
Look for "Success" in the Command Completion Status section.
3. Logoff the system.
4. Release alarm suppression when prompted.
Note:
Note:
The time that it takes to synchronize the files with the LSP depends on the
system and network resources.
5. Verify that the translations have synchronized with the LSP at the main server’s SAT
interface by typing
list survivable-processor
and press
Enter
.
6. Ensure that this LSP server is listed and registered. Look for "Y" in the
Reg
(istered) column.
Final replacement tasks
Perform the following tasks to complete the server or hard drive replacement:
1. At the Maintenance Web Pages select
Server > Status Summary
and check the overall
health of the system.
2. Run the port check tool:
a. At the server command line type
portcheck
and press
Enter
.
b. Select
Server Interface (ethX) test
(#4), and press
Enter
.
c. Ensure that the interfaces listed In the
Link
column are
up
.
3. Resolve any alarms (
Alarms > Current Alarms
).
4. Save translations (
Data Backup/Restore > Backup Now
).
5. Set backup schedules (
Data Backup/Restore > Schedule Backup
).
6. At the server command line type
productid -p
product_id
,
where
product_id
is the
product ID you received from the customer or the ART tool.
7. Re-enable alarm origination:
a. At the server command line type
almenable -d b -s y
and press
Enter
, where:
•
-d b
sets the dialout option to both numbers