20 Job Aids for Field Replacements (FRUs) for the Avaya S8510 Server
Install the replacement S8510 server in the rack
To install the replacement S8510 server back in its rack:
1. Install the server onto the slide rails in the rack (see Note in
2. Reconnect the Ethernet cable to the dual NIC at the back of the server.
3. Reconnect the power cord to the SAMP at the back of the server.
4. Reconnect the USB modem cable to the USB port on the SAMP at the back of the server.
5. Reconnect the LAN connection (if used) from the Ethernet port on the SAMP at the back of
the server.
6. Reconnect the power cord(s) to the power supply(ies) at the back of the server.
7. Push the server completely into the rack and secure into place with the captive screws on
both sides of the server.
Install Communication Manager
Set TELNET parameters
The Microsoft TELNET application might be set to send a carriage return (CR) and line
feed (LF) each time you press
Enter
. The installation program interprets this as two key
presses. You must change this before you TELNET to the server.
Note:
Note:
This procedure is performed entirely at your laptop, not on the server.
1. Click on
Start > Run
to open the Run dialog box.
2. Type
telnet
and press
Enter
to open a Microsoft TELNET session.
3. Type
unset crlf
and press
Enter
.
4. Type
display
and press
Enter
to confirm that either
Sending only CR
or
Line feed
mode--causes the return key to send CR
displays.
5. Type
quit
or close the TELNET window by clicking on the
X
in the upper-right corner.
This closes the TELNET connection and resets your Microsoft TELNET defaults, which do
not need to be set each time you use TELNET.