Media Server alarms
S8300 alarms – _WD
Maintenance of the Avaya G350 Media Gateway
313
June 2004
Table 167: Alarm #12
Number
12
Source
_WD
Event ID
18
Alarm Level
Warning
Alarm Text Description
Application Restarted
Possible Causes
An application has failed and watchdog has restarted it
successfully.
Determining Cause
Go to the Web Interface; choose Diagnostics; View System Logs;
select Watchdog Logs
Resolution
From the Web Interface, choose Alarms and Notification; select
the appropriate alarm; choose Clear
Table 168: Alarm #13
Number
13
Source
_WD
Event ID
19
Alarm Level
Minor
Alarm Text Description
Application failed unintentionally
Possible Causes
Watchdog is bringing the system down because an application has
failed to start correctly. The application may have failed to start
because the file did not exist (coincident with 7), or required
parameters for the application in watchd.conf were missing or
invalid.
Determining Cause
Go to the Web Interface; choose Diagnostics; View System Logs;
select Watchdog Logs
Resolution
1. Verify that the file named in the log exists and is executable.
2. Verify that the string in watchd.conf is correct.
3. From the Web Interface, choose Alarms and Notification; select
the appropriate alarm; choose Clear