PARTNER® Version, Installation and Reference Manual
Page 36
- Issue 1a (30 January 2010)
IP Office Essential Edition
3.2.9 Wall Mounting
The IP Office 500v2 control unit can be wall mounted. This requires an IP
Office 500 Wall Mounting Kit (SAP 700430150) plus additional 4.5mm
fixtures and fittings suitable for the wall type. The wall mounting kit
includes two brackets, one top and one bottom.
Environmental Requirements
In addition to the existing
environmental requirements
for an IP Office
system, the following additional requirements apply when wall mounting
a unit:
·
The wall surface must be vertical, flat and vibration free.
·
A minimum clearance of 500mm (19.7 inches) is required on
all sides.
·
The unit must be orientated as shown when mounted. That is
with the base card slots facing right when viewed from in front of
the unit.
·
The brackets must be used as shown, with the deeper tray-
like bracket used at the bottom of the wall mounted control unit.
·
Only the screws (M3 x 6mm) provided with the mounting kit
should used to attach the brackets to the control unit.