1000Mbps full
when PHY1STAT = 6
2. To change the Ethernet setting, press the Right navigation arrow to navigate
through the possible settings.
Depending on the current value, the next sequential text string is selected and
displayed as the setting. For example, if the current value is 10 Mbps half (2) and
if you press the Right navigation arrow, the value changes to 10 Mbps full (3). If the
current value is 1000 Mbps full (6) and if you press the navigation arrow, the value
changes to Auto (1).
3. To change the PC Ethernet setting, select that line and press the Right navigation
arrow to navigate through the possible settings.
4. Press
Save
to store the new settings and redisplay the Craft Local Procedure
screen.
Disabling and enabling event logging
About this task
Note:
When updating local Craft procedures from a touch screen deskphone, touching the line
you want to change or the applicable softkey produces the same result as selecting a line
and pressing the applicable softkey on a non-touch screen IP deskphone.
Use the following procedure to enable or disable logging of system events.
Procedure
1. When you select
LOG
from the Craft Local Procedure Screen, the deskphone
prompts you to use the Right and Left navigation arrows to select a setting and
displays the following text:
Log:
text string
Choice Selector
where the
text string
is the wording associated with the current system value of
NVLOGSTAT, defined as:
•
Disabled
when NVLOGSTAT = 0
•
Emergencies
when NVLOGSTAT = 1
•
Alerts
when NVLOGSTAT = 2
•
Critical
when NVLOGSTAT = 3
•
Errors
when NVLOGSTAT = 4
Disabling and enabling event logging
Installing and Maintaining Avaya IP Deskphone H.323 9608, 9611G, 9621G, and 9641G
August 2013 57