Manual upgrade of an S8300A and G700 to R4.0
560 Installing and Upgrading the Avaya G700 Media Gateway and Avaya S8300 Media Server
To stop Communication Manager on an LSP
Skip this procedure if no LSPs are registered to the S8300.
For configurations with LSPs, the LSPs can run the same version or a later version of
Communication Manager than the version running on the primary controller. Normally, the
primary controller and the LSPs should run the same version of Communication Manager.
Therefore, an upgrade to an LSP is usually accompanied by an upgrade of the primary
controller.
Note:
Note:
You should upgrade the LSP
before
you upgrade the primary controller.
Before you upgrade the primary controller, you need to shut down Communication Manager on
the LSPs. This prevents the phones and other endpoints attached to the G700 from trying to
register with the LSPs while you are upgrading the primary controller.
1. Open a telnet session on the S8300 (LSP).
2. Telnet to the LSP.
3. At the command line, type
stop -acfn
and press
Enter
.
The S8300 (LSP) shuts down Communication Manager.
!
CAUTION:
CAUTION:
The LSP’s Communication Manager must remain shut down while you upgrade
the primary controller. When you complete the primary controller upgrade, run
save translation
on the primary controller before restarting Communication
Manager on the LSP. The save translations process will automatically cause the
G700’s endpoints to reregister with the primary controller.
After the primary controller has been upgraded, you need to restart the LSPs.
To disable alarm origination
If alarm origination is enabled during the upgrade, unnecessary alarms will be sent to the
Operations Support System (OSS) destination number(s). Even if you selected
Suppress
Alarm Origination
when you logged in, alarm origination will be automatically re-enabled when
the system reboots after the software upgrade. Use this procedure to prevent alarm origination
from being re-enabled after reboot.
!
CAUTION:
CAUTION:
If you do not disable alarm origination, the system can generate alarms during
the upgrade, resulting in unnecessary trouble tickets.
1. Logoff the SAT session.
2. At the command prompt, type
almenable -d n -s n
, where
-d n
sets the dialout option to
neither
(number)
-s n
disables SNMP alarm origination