![Avaya G600 Installing Manual Download Page 248](http://html1.mh-extra.com/html/avaya/g600/g600_installing-manual_3027010248.webp)
248
Migrating to an Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Testing the Complete Configuration
May 2003
In some countries, this remote access interface is not allowed. Contact your Avaya
representative.
Test terminating trunk transmission
The Terminating Trunk Transmission Test provides for extension number access to 3 tone
sequences that can be used for trunk transmission testing from the distant end of the trunks.
1
Type change system-parameters maintenance and press
Enter
and go to screen 2.
2
Under TERMINATING TRUNK TRANSMISSION TEST ( Extension ), type in 3
extension numbers in the 3 fields provided:
Test Type 100:_______Test Type 102:_______Test Type 105:_______
Test connectivity to the LAN
To test the external IP connections for the C-LAN, IP Media Processor, and VAL circuit packs,
you must ping the circuit pack and ping a known computer connected to your network. If
everything is configured correctly, the Result column on the Ping Results screen reads PASS. If
it reads ABORT, verify the IP-address information and check the connectivity, including the
cabling.
1
Type ping ip-address IPaddress board UUCSS and press
Enter.
The variable IPaddress is the IP address of the circuit pack and UUCSS is the cabinet,
carrier, and slot of the circuit pack.
Test Type
Test Features
Test type 100
5.5 seconds of 1004 Hz tone at 0 dB
Quiet until disconnect; disconnect is forced after 1 minute
Test Type
102
9 seconds of 1004 Hz tone at 0 dB
1 second of silence
Cycle is repeated until disconnect, which is forced after 24
hours
Test Type
105
9 seconds of 1004 Hz tone at -16 dB
1 second of silence
9 seconds of 404 Hz tone at -16 dB
1 second of silence
9 seconds of 2804 Hz tone at -16 dB
30 seconds of silence
0.5 seconds of test progress tone (2225 Hz)
About 5 seconds of silence
Forced disconnect