Installing the Avaya™ S8700 Media Server with Avaya™ MCC1 or SCC1 Media Gateway
Installing and Wiring Telephones
May 2003
302D to 4-wire DCP Wiring
Connect Adjunct Power
The 400B2 adapter is convenient for connecting local -48 VDC power to a modular plug. See
‘‘400B2 Adapter Connecting to a Modular Plug’’ on page 166
Each port network can provide power for up to three attendant consoles. This source of power is
preferred for the attendant consoles because it has the same battery backup as the media
gateway. See
‘‘Auxiliary Connector Outputs (MCC1 and SCC1 media gateways only)’’ on page
NOTE:
Adjunct power can be provided locally at the telephone or console by either the 1151B1 or
1151B2 power supply. Adjunct power can be provided from the equipment room or
equipment closet with the 1145B power unit. Go to
‘‘Installing and Wiring Telephone
for power supply information and installation procedures.
Figure notes
1
302D Attendant Console
2
4-wire Digital Line Circuit Pack
(Position 1C02)
3
-48 VDC From Adjunct Power
4
Ground From Adjunct Power