Reset commands
Issue 4 May 2002
4-5
555-233-123
Reset System 5 (System Reboot and
Run All 24-Hour Tests)
Emergency Transfer is invoked. The LMM performs a series of diagnostics on the
processor, on memory, and on memory card. Some diagnostics perform twice.
This takes less than three minutes.
The boot image is already in the flash ROM memory. The system reboots
immediately after the LMM performs a series of diagnostics on the processor and
memory. Translations reload from the translation card. Depending on the
translation, the reloading process takes from five to 30 seconds. Thereafter, all
port circuit packs are reset, and all telephone sessions drop. Telephones begin to
reconnect to the switch within 30 seconds. In a large system, reconnection of all
telephones may take up to five minutes. Scheduled maintenance is initiated.
MEMORY FUNCTIONAL TEST
PASSED
MEMORY MODULE A STUCK BIT TEST
PASSED
MEMORY MODULE A PARITY TEST
PASSED
MEMORY MODULE A BURST TEST
PASSED
MEMORY MODULE B STUCK BIT TEST
PASSED
MEMORY MODULE B PARITY TEST
PASSED
MEMORY MODULE B BURST TEST
PASSED
MEMORY MODULE C STUCK BIT TEST
PASSED
MEMORY MODULE C PARITY TEST
PASSED
MEMORY MODULE C BURST TEST
PASSED
VIRTUAL MEMORY TEST
PASSED
EXECEPTION TEST
PASSED
TIMER TEST
PASSED
MTP TEST
PASSED
SANITY TIMER TEST
PASSED
ADDRESS MATCHER TEST
PASSED
FLASH TEXT CHECKSUM TEST
PASSED
DECOMPRESSING IDATA
in_cnt = 455532,
out_cnt = 1802240
RAM DATA CHECKSUM TEST
PASSED
RESET 4 (EXT REBOOT) PEFORMED
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...