Maintenance Object Repair Procedures
555-233-123
10-166
Issue 4 May 2002
ANNOUNCE (Announce)
The ANNOUNCE MO logs an error in the hardware error log if at least one of the
following is true:
■
The save announcements or restore announcements command does
not complete successfully, or the
■
System fails to restore announcements from the memory card [386 system]
or tape [286 system] at boot time.
Figure 10-4 shows the connection of the Announcement Circuit Pack to the
system. To save or restore announcements, an ANNOUNCEMENT Data
Extension must be administered, and at least one DATA-CHL (Network Control
Data Channel) must be in the in-service/idle state.
Figure 10-4.
Connection of Announcement Circuit Pack to the System
MO Name (in
Alarm Log)
Alarm Level
Initial Command to
Run
Full Name of MO
ANNOUNCE
none
none
ANNOUNCEMENT
Switch
software
applications
DATA-CHL
software
DATA-CHL
software
DATA-CHL
software
DATA-CHL
software
PR-MAINT
Tape
drive
Memory bus
Network control
DATA
CHL1
DATA
CHL2
DATA
CHL3
DATA
CHL4
CARD-MEM
TDM bus
Announcement
circuit pack
Processor
cydf0089 LJK 031201
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...