Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-358
Issue 4 May 2002
status data-module
This command displays internal software state information for diagnosis. This
command can help locate facilities to which the data module is communicating.
0x62 (0t98)
ISDN protocol error
0x64 (0t100)
ISDN protocol error
0x66 (0t102)
ISDN timer expired
0x7f (0t127)
Reason unknown
0xC2 (0t194)
Ring no answer
0xC8 (0t200)
Hi and dry - no feedback detected
0xC9 (0t201)
Cascade link administered wrong
0xCA (0t202)
CPTR not available to detect failure
Action/Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
busyout mis
extension
data module extension
Report prints if a printer is linked to
the SAT.
Examples:
status data-module 30000
status data-module 32770
status data-module 32770 print
init
inads
craft
cust
rcust
bcms
browse
none
none
Table 8-14.
Status AC - Failure Cause Values — Continued
Failure Cause
(hexadecimal)
Description
Continued on next page