Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-134
Issue 4 May 2002
enable test-number
This command enables a previously disabled test number. At the next request by
maintenance or the technician, this test number runs.
get boot-image
Use this command to view the two firmware image parameters on the TN2501AP
circuit pack.
Screen 8-13.
Display Firmware Image(s) screen
Action/
Object
Qualifier
Qualifier
Description
Logins
Defaults
Feature
Interactions
enable
test-number
number
The test number to
re-enable
Example:
enable test-number
102
init
inads
craft
none
display
disabled-tests
gives a list of all
disabled tests.
Action/
Object
Qualifier
Qualifier Description
Logins
Defaults
Feature
Interactions
get boot-
image
location
The physical location of the
circuit pack (UUCSS).
Example
get boot-image 1C07
init
inads
craft
customer
get boot-image 1C07
DISPLAY FIRMWARE IMAGE(S)
Image 1 Image 2
Board Type: TN2501 TN2501
FW Vintage: 02 02
HW Signature: 02 02
Suffix: A A
Date: 03/02/02 03/02/01
Timestamp: 10:30:50 12:42:18
CRC Checksum: Good Good
Active Image: Yes No
Reboot Image: Yes No
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...