
upgrade software
Issue 4 May 2002
A-153
555-233-123
upgrade software
Help Messages
If the system technician presses
HELP
after entering “upgrade software,” the
following message appears:
Entry is not required
If no card-mem is loaded into the system, the following message appears:
Software card-mem is not inserted in the system
If a wrong card-mem is loaded into the system, the following message appears:
Incorrect card-mem loaded; insert software card-mem
If the directory information on the software card-mem is corrupted or the
card-mem is not formatted properly, the following message appears:
Software card-mem not readable; try another card-mem
If this command is in conflict with another currently executing command, then a
message appears showing the login id of the conflicting user and the conflicting
command. The message is as follows:
’login id’:’command’ has a command conflict
If the checksum on the software card-mem is bad, the following message
appears:
Bad checksum on software card-mem; try another card-mem
If the software upgrade failed in the standby SPE, the following message appears:
No response on upgrade status from standby SPE, command failed
If the software card-mem in the standby SPE is not replaced with a translation
card-mem within 2 minutes, the following message appears:
No translation card-mem inserted
in the standby SPE, command aborted
If the flash text checksum failed after the standby upgrade, the following message
appears:
Standby SPE text checksum failed, command aborted
If the software card-mem is not inserted in the active SPE within 2 minutes after
the prompting string: “REPLACE TRANSLATION CARD-MEM ON <active
carrier> WITH SOFTWARE CARD-MEM,” the command has to be retried again
and the following message appears:
No software card-mem inserted in active SPE; command aborted
If the SPE-select switches are thrown to prevent the SPE-interchange during a
software upgrade, the following message appears:
SPE select switches thrown; upgrade complete only on standby
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...