Error Messages from Chapter 8: Maintenance
Commands
555-233-123
A-18
Issue 4 May 2002
Output (Page One)
The following output example shows a display of Page 1 of the change
system-parameters maintenance command.
Field Descriptions (Page One)
Action/Object
Qualifier
Qualifier Description
Permissions
Defaults
Feature
Interactions
change
system-parameters
maintenance
Examples:
change system-parameters
maintenance
init
inads
craft
cust
rcust
none
none
Operations Support Parameters
Product
Identification
Identifies switch to an Operations Support System (OSS): 10-digit number
starting with 1.
First OSS
Telephone
Number
Switch reports alarms first to the First OSS telephone number (for example,
INADS or Trouble Tracker). The number must be obtained from the National
Customer Support Center (NCSC) or the TSC. (# and * are not allowed in the
telephone number.)
Abbrev Alarm
Report
Enables the Abbreviated Alarm Report feature for the first OSS. (yes)
change system-parameters maintenance Page 1 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
Product Identification: 1000000000
First OSS Telephone Number: 5551212 Abbrev Alarm Report? y
Second OSS Telephone Number: 5551213 Abbrev Alarm Report? n
Alarm Origination to OSS Numbers: both
Cleared Alarm Notification? y Suspension Threshold: 5_
Restart Notification? y
Test Remote Access Port? n
CPE Alarm Activation Level: none
Packet Bus Activated? n
Customer Access to INADS Port? n
Repeat Dial Interval (mins): 7
SCHEDULED MAINTENANCE
Start Time: 22: 00 Stop Time: 04: 00
Daily Maintenance: daily Save Translation: daily
Command Time-out (hours): 2
Control Channel Interchange: no System Clocks Interchange: no
SPE Interchange: no EXP-LINK Interchange: no
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...