Maintenance Object Repair Procedures
555-233-123
10-1974
Issue 4 May 2002
VC-DSPPT
Each Voice Conditioner Circuit Pack (VC-BD) provides two types of resources:
1. Transcoder Resources used for encoding and decoding audio formats
2. Summer Resources used for summing audio from different sources
The eight Voice Conditioner DSP ports are the transcoder resources on the
VC-BD.
Error Log Entries and Test to Clear Values
Notes:
a. This port has been busied out by the busyout port PCSSpp command.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier designation (for
example, A, B, C, or D); and SS is the address of the slot in the carrier where the circuit pack is
located (for example, 01, 02, ...).
Full Name of MO
VC-DSPPT
MAJOR
test port PCSSpp l r#
Voice Conditioner DSP Port
VC-DSPPT
MINOR
test port PCSSpp l r#
Voice Conditioner DSP Port
VC-DSPPT
WARNING
test port PCSSpp l r#
Voice Conditioner DSP Port
Table 10-708.
VC-DSPPT Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/ Off
Board
Test to Clear Value
0
1
1
Run the short test sequence first. If all test pass, run the long test sequence. Refer to the appropriate
test description and follow the recommended procedures.
0
Any
Any
Any
test port PCSSpp sh r 1
18 (a)
0
busyout port PCSSpp
WNG
OFF
release port PCSSpp
257 (b)
Any
NPE Crosstalk Test (#6)
MIN
ON
test port PCSSpp 1 r 3
513 (c)
Any
VC DSP Port Local TDM
Loopback Test (#1104)
MIN
ON
test port PCSSpp sh r 3
778 to
781 (d)
Any
VC Port Reset DSP Test
(#1106)
MAJ
ON
See note (d)
1025 (e)
WNG
ON
1281 (f)
Any
VC DSP Port DSP
Loopback Test #(1105)
MIN
ON
test port PCSSpp sh r 3
3840 (g)
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...