busyout board
Issue 4 May 2002
8-3
555-233-123
Field descriptions
busyout board
This command puts all the ports associated with the specified access endpoint in
a maintenance busy (craft busy) state. No periodic or scheduled tests are
performed on the busied out access endpoint ports until they are released. When
the access endpoint ports are maintenance busy, the access endpoint is removed
from active service on the switch, meaning that no call processing activity can
include the busied objects because terminals on the administered ports do not
receive dial-tone. Warning alarms are generated on each busied out port in the
access endpoint. The release access-endpoint command returns all the ports
associated with the specified access endpoint to operation.
!
WARNING:
This command is service disrupting and may cause extraneous alarms.
Port
Port address (cabinet-carrier-slot-circuit)
Maintenance Name
Name of maintenance object (WAE-PORT = wideband
access endpoint; TIE-DS1 = single port access endpoint)
Alt. Name
The alternate way of identifying the maintenance object - the
extension number of the access endpoint.
Result
Test result: Pass, Fail, Abort
Error Code
Numeric code explaining why the release failed or aborted.
Refer to the detailed list of the codes by test number for
each MO.
Action/Object
Qualifier
Qualifier
Description
Logins
Defaults
Feature
Interactions
busyout board
location
Board address
(PCSSpp)
Examples:
busyout board 01c11
busyout board 02c15
init
inads
craft
none
none
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...