Maintenance Commands and Trouble-Clearing Aids
555-233-123
8-2
Issue 4 May 2002
busyout access-endpoint
This command is destructive.
This command busies out a specified access endpoint.
Feature Interactions
■
If there is an active call on the specified access endpoint, this command
causes the call to drop.
Output
The following example shows the output for busyout access-endpoint 22502
and assumes that access endpoint ports for extension 22502 are in cabinet 1,
carrier C, slot 11, circuit 1 to 6. The responses display on a test-by-test basis with
one line of data for each test result.
Action/
Object
Qualifier
Qualifier
Description
Logins
Defaults
Feature
Interactions
busyout
access-
endpoint
extension
Extension number of
access endpoint (per
dial-plan)
Examples:
busyout
access-endpoint
25012
busyout
access-endpoint
77868
init
inads
craft
nms
none
See below
busyout access-endpoint 22502 SPE A
COMMAND RESULTS
Port Maintenance Name Alt. Name Result Error Code
01C1101 WAE-PORT 22502 PASS
01C1102 WAE-PORT 22502 PASS
01C1103 WAE-PORT 22502 PASS
01C1104 WAE-PORT 22502 PASS
01C1105 WAE-PORT 22502 PASS
01C1106 WAE-PORT 22502 PASS
Command Successfully Completed
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...