LED Interpretation
555-233-123
7-2
Issue 4 May 2002
Terminal Alarm Notification
Terminal Alarm Notification is an optional feature which displays several types of
alarms on voice terminals with administered feature buttons or the attendant
console. A maximum of ten digital and/or hybrid voice terminals may be used.
When an alarm occurs, the green status LED associated with the assigned button
will be in a steady state. The lamp may be turned off by pressing the button
associated with the lighted alarm lamp. If the lamp is turned off, and the alarm has
not been resolved by the time maintenance reschedules testing, the green status
LED will resume its steady state. The following alarms are displayed:
ac-alarm
Administered Connection Alarm: a locally administered connection
(ADM-CONN) has a Major, Minor, or Warning alarm active.
pr-awu-alm
Auto Wakeup Journal Printer Alarm: the automatic wakeup journal
printer has a Major, Minor, or Warning alarm active.
off-bd-alar
m
DS1 or ATM Facility Alarm: an off-board Major, Minor, or Warning
alarm is active on a DS1-BD, UDS1-BD, or ATM-TRK board.
trk-ac-alm
Facility Access Alarm: The facility access trunk test feature is
activated.
major-alrm
Major Alarm: The system has logged a Major Alarm.
mj/mn-alrm
Major/Minor Alarm: The system has logged a Major or Minor Alarm.
pr-pms-alm
PMS Printer: The Property Management System printer has a Major,
Minor, or Warning alarm active.
rs-alert
Reset-Alert: reset system 2 or 3 has been performed.
cdr1-alrm
Call Detail Recording Alarm: The Primary CDR Link has a Major,
Minor, or Warning alarm active.
cdr2-alrm
Call Detail Recording Alarm: The Secondary Link has a Major, Minor,
or Warning alarm active.
pr-sys-alm
System Printer Alarm: The System Printer (SYS-PRNT) has a Major,
Minor, or Warning alarm active.
pms-alarm
The Property Management System has a Major, Minor or Warning
alarm active.
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...