Maintenance Object Repair Procedures
555-233-123
10-1416
Issue 4 May 2002
PROC-SAN (Process Sanity Audits)
The Process Sanity Audits MO is responsible for monitoring the sanity of software
processes in the system. If the Process Sanity Audits MO detects that a process
has gone insane (does not respond to a sanity message within an allotted time
period), the process is restarted. If the Process Sanity Audits MO detects that
multiple processes (or a single key process) do not respond to sanity messages
within an allotted time period, a system recovery action is initiated.
The Process Sanity Audits MO has no alarms and no tests. Certain errors are
logged to the Hardware Error Log for information purposes only.
Error Log Entries and Test to Clear Values
Notes:
a. These errors indicate that a system recovery action has been taken
because one or more software processes failed to respond to a sanity audit
in a timely fashion. As a result of the recovery action, the system may have
temporarily suspended service for a period of time surrounding the error.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
PROC-SAN
none
none
Process Sanity Audits
Table 10-531.
Process Sanity Audits Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1
Look for other errors of the same type and deal with them accordingly.
0
Any
Any
Any
none
10 (a)
0
none
none
none
none
204 (a)
any
none
none
none
none
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...