
Maintenance Object Repair Procedures
555-233-123
10-1202
Issue 4 May 2002
PE-BCHL (PRI Endpoint Port)
A PRI Endpoint provides ISDN-PRI (Primary Rate Interface) connections for
customers with application equipment or terminal adapters that terminate
ISDN-PRI. The equipment or terminal adapters are connected to the switch via
the UDS1 interface circuit pack. PRI Endpoint Port (PE-BCHL) maintenance
provides a strategy to maintain PRI Endpoint Port hardware circuitry on the UDS1
circuit pack. The maintenance strategy involves logging PRI Endpoint Port
hardware errors, running tests for port initialization, periodic and scheduled
maintenance, system technician-demanded tests, and alarm escalation and
resolution.
Wideband Switching
The Wideband Switching capability supports end-to-end connectivity between
customer endpoints at data rates from 128 to 1536 kbps over T1 facilities and to
1984 kbps over E1 facilities. DEFINITY switching capabilities are extended to
support wideband calls comprised of multiple DS0s that are switched end-to-end
as a single entity.
The Wideband Switching capability is designed for ISDN application equipment
(for example, ISDN video codecs), but it retains provisions for non-ISDN
application equipment by using PRI terminal adapters. In the same sense that a
DEFINITY data module acts as a DCP or BRI terminal adapter between endpoint
data (for example, V.35) and dialing (for example, RS-366) interfaces and a DCP
interface, a PRI terminal adapter acts as a wideband terminal adapter between
endpoint data and dialing interfaces and DEFINITY’s line-side ISDN PRI interface.
The Wideband Switching Capability introduces PRI Endpoints on DEFINITY
line-side interfaces. A PRI Endpoint consists of one or more contiguous
B-channels on a line-side T1 or E1 ISDN PRI facility, and it has an extension
number. Endpoints initiate and receive calls using ISDN SETUP messages that
indicate the data rate and specific B-channels to be used, and they communicate
all other call status information via standard ISDN messages. Any DEFINITY
ISDN signaling set (for example, AT&T, CCITT, ECMA) may be used for a
line-side ISDNPRI facility.
MO Name (in
Alarm Log)
Alarm
Level
Initial Command to Run
Full Name of MO
PE-BCHL
1
1
For additional repair information, see also UDS1-BD (UDS1 Interface Circuit Pack)
maintenance documentation and
‘‘Troubleshooting PRI Endpoint Problems’’
MINOR
test port PCSSpp l
PRI Endpoint Port
PE-BCHL
WARNING
test port PCSSpp sh
PRI Endpoint Port
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...