Maintenance Object Repair Procedures
555-233-123
10-1040
Issue 4 May 2002
NOTE:
Local restore of a complete system from the PCMCIA disk should not
require more than 20 minutes assuming that a replacement MAPD pack is
available and pre-loaded with the IP trunk application software.
Restoring data from the PCMCIA disk
Before you start
1. Shut down the application running on the circuit pack. See
2. Remove the defective IP Trunk circuit pack from the switch (if applicable).
3. Install the replacement IP Trunk circuit pack in the switch (if applicable).
4. Insert the backup diskette into the IP Trunk circuit pack.
Table 10-377.
Backing up TN802 administration data
Step
Description
Comments
1.
Busyout circuit pack
At the Avaya DEFINITY Server terminal type
busyout board UUCSS (the address of the
TN802 circuit pack) and press
Enter
.
2.
Backup administration
TN802 to disk
At the Windows NT desktop, double-click on the IP
Trunk Backup Restore icon.
The IP Trunk Backup/Restore Utility screen
appears.
3.
Select utility
In the IP Trunk Backup/Restore Utility dialog
screen, click on Files, Backup.
The IP Trunk Backup screen appears.
4.
Select backup
In the IP Trunk Backup screen, click on the
Backup button
5.
Wait
Backup can take as much as 20 minutes to
complete.
6.
Release circuit pack
At the Avaya DEFINITY Server terminal type
release board UUCss (the address of the TN802
circuit pack) and press
Enter
.
Continued on next page
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...