
Maintenance Object Repair Procedures
555-233-123
10-292
Issue 4 May 2002
BRI-SET, ASAI-ADJ, BRI-DAT
!
CAUTION:
A detailed flowchart for isolating and resolving Packet Bus faults is included
in Chapter 9, “Packet Bus Fault Isolation and Correction”. This flowchart,
along with the other information presented in the chapter, can help in
resolving problems that involve more than a single station or circuit pack.
Whenever the repair procedures for this Maintenance Object refer to Packet
Bus and/or Packet Control maintenance, be sure to reference Chapter 9,
“Packet Bus Fault Isolation and Correction” in addition to the relevant MO
documentation.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
1
1
Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier designation (A,
B, C, D, or E); SS is the address of the slot in the carrier where the circuit pack is located (01, 02,
etc.); and pp is the 2-digit port number (for example, 01). The alternate name field contains the
extension of the endpoint. This field is used to distinguish between endpoints on the same port.
Full Name of MO
BRI-SET
WARNING
2
2
The alarm level for ASAI and Avaya adjuncts may be administered using the set options command.
The alarm level can be set independently for Off-Board and On-Board alarms to WARNING,
MINOR, or MAJOR for all ASAI and Avaya adjuncts in the system.
test station extension l,
test data-module extension
ISDN-BRI Set
ASAI-ADJ
MAJOR
2
test station extension
ASAI-Adjunct
ASAI-ADJ
MAJOR
2
test data-module extension
ASAI-Adjunct
ASAI-ADJ
WARNING
3
3
Alarming for an ASAI and Avaya adjuncts is disabled if the adjunct asks the switch to suspend
maintenance. When this occurs, an error and a WARNING alarm are logged against the endpoint.
Busying out and releasing the ASAI station or ADJLK station will clear the alarm.
test data-module extension
ASAI-Adjunct
ATT-ADJ
MAJOR
2
test station extension
Avaya-Adjunct
ATT-ADJ
MAJOR
2
test station extension
Avaya-Adjunct
ATT-ADJ
WARNING
3
test station extension
Avaya-Adjunct
LGATE-AJ
MAJOR
2
test station extension
Ethernet ASAI-Adjunct
LGATE-AJ
MAJOR
2
test station extension
Ethernet ASAI-Adjunct
LGATE-AJ
WARNING
3
test station extension
Ethernet ASAI-Adjunct
ATTE-AJ
MAJOR
2
test station extension
Ethernet Avaya-Adjunct
ATTE-AJ
MAJOR
2
test station extension
Ethernet Avaya-Adjunct
ATTE-AJ
WARNING
3
test station extension
Ethernet Avaya-Adjunct
BRI-DAT
test data-module
Summary of Contents for Definity SI
Page 1: ...0DLQWHQDQFH IRU YD D 1 7 6HUYHU 6 Volumes 1 2 and 3 555 233 123 Issue 4 May 2002...
Page 62: ...Maintenance Architecture 555 233 123 1 26 Issue 4 May 2002...
Page 92: ...Management Terminals 555 233 123 3 26 Issue 4 May 2002...
Page 204: ...Routine Maintenance Procedures 555 233 123 5 100 Issue 4 May 2002...
Page 250: ...LED Interpretation 555 233 123 7 10 Issue 4 May 2002...
Page 2804: ...Maintenance Object Repair Procedures 555 233 123 10 2018 Issue 4 May 2002...