Add Pooled Modem
Issue 7 November 2003
7-29
555-233-115
Add Pooled Modem
Modem pooling supports two types of conversion resources: integrated and
combined.
An integrated conversion requires a Pooled Modem circuit pack for each 2
conversion resources provided.
A combined conversion requires a port of a TN745B or TN2136 Digital Line circuit
pack and a port of either an 8-port TN742, TN769, a 16-port TN746B, or a 24-port
TN793/B, TN2793/B Analog Line circuit pack for each conversion resource
provided.
The pooled modem requires a WP90110 L7 power supply. Although integrated
conversion can use either the L5 or L7, the combined only works with an L7.
!
CAUTION:
The L5 and L7 power supplies look identical. Check the label to be sure you
have the L7 before installing.
Determine the port assignment of the circuit packs to be added (if required).
3. Install the appropriate circuit packs in assigned carrier slot (if required).
4. For Paradyne 3800 series modems:
a. Type AT&F&D2&S4\D3S2=128x7V2S7=60S85=1 and press
Enter
.
b. Type ATY0S10=100S78=2M0E0\N1&W and press
Enter
.
5. For other types of modems, refer to the vendor’s documentation.
Settings for Modem Connected to Data Module
1. Type add data-module next and press
Enter
.
2. Type pdm in the
Type
field.
3. Type x in the
Port
field.
4. Type dte in the
Connected to
field and press
Enter
.
5. Type add station next and press
Enter
.
6. Type 2500 in the
Type
field.
7. Type x in the
Port
field.
8. Type n in the
Tests
field and press
Enter
.
9. Type add modem-pool next and press
Enter
.
10. Type combined in the
Group Type
field.
11. Type 5 in the
Hold Time (min)
field.
12. Type two-way in the
Direction
field.
13. Type 9600 in the
Speed
field.