Adding or Removing Cabinet Hardware
555-233-115
7-26
Issue 7 November 2003
Add DID Trunks
Requirements
Each Direct Inward Dial (DID) trunk connects to 1 port DID Trunk circuit pack or to
1 port of an assortment of DID trunk circuit packs.
Installation
1. Determine the port assignment of the trunk from the Trunk Group form.
2. Install a DID Trunk circuit pack in assigned carrier slot (if an additional
circuit pack is required).
3. Administer forms listed under “DID Trunk Group” in Administrator’s Guide
for Avaya Communication Manager.
Add Tie Trunks
Requirements
Each tie trunk connects to 1 port of a 4-port tie trunk circuit pack or to an
assortment of international tie trunk circuit packs.
Installation
1. Determine the port assignment of the trunk from the trunk group screen.
2. Install the tie trunk or an international tie trunk circuit pack in assigned
carrier slot (if an additional circuit pack is required).
3. For customer-owned (not leased) tie-trunk facilities (such as campus
environments), tie trunk circuit packs provide signaling capabilities beyond
those specified by the industry-wide E&M standard. Use
and
to choose the preferred signaling format, set switches on the
circuit pack, and administer the port.
EXAMPLE:
3
A
07
01
Cabinet (Port
Network)
Carrier Slot
Number
Port
Number
EXAMPLE:
3
A
07
01
Cabinet (Port
Network)
Carrier Slot
Number
Port
Number