DEFINITY Enterprise Communication Server Release 9
Installation and Maintenance for Survivable Remote EPN
555-233-121
Issue 2
November 2000
SREPN Installation
1-31
Test the SRP
1
Test the survive mode function
1. Type list cabinet and press
Enter
on the R9r system. Determine which EPN
is “watched” by Survivable Remote equipment by looking for the lower-
case “
s
” before the letters “EPN” in the
Type
field as shown in
Figure 1-15
.
There may be more than 1 EPN designated as Survivable.
Figure 1-15.
List cabinet screen
2. Type status health and press
Enter
on the Release 9r system. The status
of the SREPN should be “up.” See
Figure 1-16
.
Figure 1-16.
Status health screen (Release 9r)
list cabinet SPE B
CABINET REPORT
No. Type Layout Room Floor Building A B C D E
1 PPN 5-car CS_1 1 ABC_DE PN 01 PN 01 PN 01 SN 01 SN 01
2 sEPN 5-car CS_1 1 ABC_DE PN 04 PN 04 PN 04 PN 16 PN 16
3 EPN 5-car CS_1 1 ABC_DE PN 05 PN 05 PN 05 SN 44 SN 44
4 EPN 5-car B-32 B VWX_YZ PN 06 PN 06 PN 06 SN 07 SN 07
5 EPN 5-car 2-12 2 MNO_PQ PN 08 PN 08 PN 08 SN 09 SN 09
6 EPN 5-car E-51 1 VWX_YZ PN 10 PN 10 PN 10 SN 11 SN 11
status health SPE A
PNC: A-PNC/auto B-PNC/functional ALARMS: Maj: 2 Min: 2 Wrn: 104
Pwr: comm Sync:loc l Logins:2 BUSYOUT: Trk 0 Stn: 0 Oth: 18
Cab EmTr Mj Mn Wn PNC Cab EmTr Mj Mn Wn PNC Cab EmTr Mj Mn Wn PNC
1 auto- 0| 0|47 up
2 auto- 0| 0|12 up