Configuration
Prerequisites
DMLS requires DAP Controller to always be active.
Configuring DECT Messaging and Location Service
The following configuration is required to enable interworking between DMLS and SIP DECT
system (DAP Controller):
1. Add a new system using a right button of the mouse on the field in the
DECT system
tab.
2. Enter system name, SIP DECT system PARI, DAP Controller IP address, port
28001, Application port (for example, 2010).
3. Enter the license type: Basic for messaging functionality or Location for additional
location detection functionality.
4. Enter the key and press
OK
.
5. If you have a location license and Ekahau software click
Settings
tab and enter
Ekahau RTLS controller IP address in the section Location Engine IP address
(default port 8552).
6. Select
Service
menu and click start to launch the service.
If the connection is established, the Link is changed to up, License status – to
Valid.
7. Create an ssh connection to the IP address, where DMLS is running, using a
configured application port (for example, 2010).
Note:
A tool for creating an ssh connection or any software for performing automatic operations
with DMLS is not provided.
When DMLS establishes a connection to DAP Controller and you set up a connection to DMLS,
you can send service commands according to the DMLS interface specification. Refer to
Client
interface description DECT Messaging and Location Service
provided with the DMLS software
package.
DECT Messaging and Location Service
268 SIP DECT Fundamentals
October 2012
Summary of Contents for CS 1000
Page 6: ...6 SIP DECT Fundamentals October 2012 ...
Page 146: ...System administration 146 SIP DECT Fundamentals October 2012 Comments infodev avaya com ...
Page 174: ...System maintenance 174 SIP DECT Fundamentals October 2012 Comments infodev avaya com ...
Page 204: ...Site survey example 204 SIP DECT Fundamentals October 2012 Comments infodev avaya com ...