Troubleshooting startup problems
on page 29
Startup diagnostic codes
HEX display diagnostic codes are divided into the following two categories:
• critical startup diagnostics
• non critical operating system and switch diagnostics
Critical startup diagnostic codes
All critical startup diagnostics must pass before the 202i can proceed with the start sequence. If
a critical diagnostic fails, the start sequence indefinitely halts, an error code displays, and you
here a continuous beep.
The following table shows the critical startup diagnostic codes with their corresponding failure
codes. Failure of these diagnostics means that there has been a server failure. The start cycle
halts.
Note:
When a test succeeds, the next test code appears.
Test code
Test description
Failure code
T:01
Internal RAM self-test
F:01
T:02
ALU self-test
F:02
T:03
Address mode self-test
F:03
T:04
Boot ROM self-test
F:04
T:05
Timer self-test
F:05
T:06
Watchdog self-test
F:06
T:07
EEPROM self-test
F:07
T:08
End of system controller self-tests
The power status LED blinks three times.
not applicable
HOST
Start of BIOS diagnostics
The monitor displays the BIOS start screen.
If a critical error occurs, the start cycle halts.
Examples of critical errors are memory
HOST continues to
scroll across the HEX
display