Issue 2 July 2005
213
Chapter 12: Troubleshooting the Installation
Troubleshooting the Installation
This section will allow you to perform basic troubleshooting of the installation. If you are unable
to solve the problem after following the procedures in this chapter, please contact Avaya
Technical Support.
Table 35: Troubleshooting
1 of 3
Problem/Cause
Suggested Solution
Switch does not power up
●
AC power cord not
inserted or faulty
●
Check that the AC power cord is
inserted correctly
●
Replace the power cord
If the cord is inserted correctly, check that the AC power source is
working by connecting a different device in place of the C360.
●
If that device works, refer to the next step.
●
If that device does not work, check the AC power
●
C360 AC power
supply not functioning
●
Use an optional BUPS (Backup
Power Supply)
●
Contact your local Avaya
distributor.
The power supply is
not user-replaceable
.
No data on 10/100 Mbps link
●
Faulty cable
●
Replace the cable
●
Mis-configuration
●
Use the
show port
CLI
command to show the port
parameters and check they are
compatible with the attached
device.
●
Faulty NIC
●
Replace the NIC
1 of 3
Summary of Contents for C360 Manager
Page 17: ...Issue 2 July 2005 17 Section 1 Avaya C360 Overview...
Page 18: ...18 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches version 4 5...
Page 29: ...Issue 2 July 2005 29 Section 2 Installing the C360...
Page 30: ...30 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches version 4 5...
Page 91: ...Issue 2 July 2005 91 Section 3 Avaya C360 Configuration...
Page 92: ...92 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches version 4 5...
Page 211: ...Issue 2 July 2005 211 Section 4 Troubleshooting and Maintaining the Avaya C360...
Page 212: ...212 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches version 4 5...