CHAPTER 8
Instructions, use and maintenance manual
D r a g o P Z e r o
Page 65
8. TROUBLESHOOTING
8.1. INTRODUCTION
CAUTION!
ALL TROUBLESHOOTING OPERATIONS MUST BE CARRIED OUT WITH THE BURNER
SWITCHED OFF.
PROBLEM
CAUSE
SOLUTION
SOOT ON THE
CUPOLA
• Burner (air/gas ratio) not properly adjusted (less air).
• Unsuitable environment (proper ventilation suction).
• Chimney dirty/closed.
• Burner under the oven without oxygen.
•
Cleaning of the flue in case of conversion of wood-burning
oven.
•
Repeat the phases of the first ignition, paying special
attention to the air and gas settings.
• Room ventilation check.
• Spacer washers are missing between the burner and the
flange sleeve
• Burner compartment with special opening.
• In case of suction in the room: you will need to size the
air intake of the room in addition to the air burned by the
burner, and also take into account the air extracted by the
hook.