Avant 735
Service and maintenance
127
.
Electric system & fuses
Fuses
Locations of the fuse boxes are shown in this
chapter. In the event of electric malfunction, always
check the fuses first. If a fuse is blown repeatedly,
search for cause of burning fuse. Electric cables may
be damaged. Contact Avant service, if necessary.
If any of fuse or relay needs to be replaced, make
sure to always use correct type of spare parts.
Always use fuses and relays with correct rating.
Wrong types of fuses or relays can cause risk of fire
or damage to wiring or other electric components.
Main fuse box L and ROPS
On loaders equipped with ROPS canopy or cab L,
the fuse box is located outside the cab, on the right
side of the loader boom. Lift the boom first for easier
access to the main fuses, if possible.
Remember to
use the service support.
If the boom cannot be
lifted, the fuses can be checked after removing the
right side cover plate.
Main fuse box cab LX and DLX
On loaders equipped with cab LX and DLX, the main
fuse box is located at the front of the loader, on the
right side of the loader under a metal cover.
12 V Fuse box 1
1
12 V ON-OFF Opticontrol
2
Lights
Road traffic lights
3
Parking brake
4
Warning beacon
5
12 V electric socket
12V switches of Opticontrol
6
Extra work lights
12 V Fuse box 2
1
Hydraulic oil cooler
2
Fuel pump
Reverse beeper
3
Seat heater
Horn
4
Boom floating
5
Windscreen wiper and washer
Heater fan (Cab LX or DLX)
6
Hydraulic attachment locking
Hydraulic oil cooler fan fuse
The red indicator on the dashboard indicates blown
hydraulic oil cooler fan fuse. If the indicator is lit,
check the 25 A fuse of the oil cooler fan. Check that
the cooler fan is clean, can rotate freely, and is not
blocked. Contact Avant service if necessary.