![AV-GAD EasyLoader AV-702 Installation Instructions Download Page 1](http://html1.mh-extra.com/html/av-gad/easyloader-av-702/easyloader-av-702_installation-instructions_3023945001.webp)
AV-706
&
AV-701 Series
INSTALLATION
INSTRUCTIONS
Description
The
AV-706
and
AV-701
Series
4-wire Remote Control Station
and
Programmer Keypad
are
designed for use with
Av-Gad EASYLOADER
Control Panels.
AV-706
fits only the PRO panels.
The
AV-706
and
AV-701
Series are easy to install and to use keypads. Large 7-Segment and LCD
alphanumeric display provide readout for all control panels information and zone identification.
Installation Instructions
Press Down firmly on both tabs and pull
l
Before handling keypad, make sure your
hands are clean
l
Do not use unnecessary force in opening
and closing the keypad
l
Protective Miler sheet may be pilled from the
panel after installation is complete
Step One: Opening the keypad
Locate the two rectangular tabs on the top
of the keypad (about 35 mm / 1.5 inches
from each side). Press down on both
tabs firmly and pull front panel of keypad
toward you from the top (see Figure 1.)
Figure 1: Opening the k e y p a d
Step Two: Mounting onto Wall
Place the keypad on wall, at 1.5-1.8 meters height. Make sure the two “UP” arrows word, are
upwards. Attach housing to wall with flat-head screws (use screws that are suitable for the wall
material).
Before affixing to wall, make sure all wires have been inserted through the opening in the
rear of housing. If wires come up from the floor, they may be inserted through the square
slot on the left side of the rear housing. (Using a small screwdriver, try opening the slot with a
twisting action.)
Step Three: Wiring
Insert wires through the opening in the rear of housing. (Note maximum wire lengths in the
following table.) Make sure keypad wires are as far away as possible from telephone and
high power radio transmitter or other electrically “noisy” wires or appliances. For longer run
distance use thicker wire, e.g. 1 mm
2
.
It is recommended to run keypad wires separately in a 4 or 6 wire cable. Do not run
telephone, sensors or main electric wires in the same cable or electric pipe.
Keypad
Function
Terminals
Terminal
AV-2016/P
AV-2004/48
AV-2005
AV-2008
OR
Data
OR
OR
OR
OR
YE
Strobe
YE
YE
YE
YE
+12V
+ Power
+12V
+12V
+12V
+12V
*
7
4
1
0
8
5
2
#
9
6
3
Siren
Shunt
Display
Status
Delay
Delete
Chime
Test
Program
Reset
Shunt
Telephone
ARMED
STATUS
SHUNT
FIRE
ZONE
DISPLAY
EASYLOADER AV-701
AV-GAD