26
8. Maintenance
8-1 Troubleshooting Guide
Many error codes many appears on this air conditionor, and this troubleshooting
guide is prepared for the maintenance personnel to detect the error position and the
parts to be replaced during the troubleshooting process. In this Guide, the
Troubleshooting Method is guided by the Error Name, and the Reference Code under
the General Index is the error code of the Indoor Unit of the mainstream model
supplied by the Company.
Example:
“Indoor Unit coil sensor error” is coded as E3 in the error code of the
Indoor Unit, but appears as flash-out via the trouble light of the Outdoor Unit machine.
However, their troubleshooting method is the same, and use the same table as well.
General index: fix speed air conditioners only involve E1, E2, E3 and E4
No.
Error Name
Reference Code
1
Overcurrent Protection of Indoor Unit
E0
2
Indoor Unit temperature sensor error
E1
3
Outdoor Unit coil sensor error
E2
4
Indoor Unit coil sensor error
E3
5
Indoor Unit motor error of
wall mounted air
conditioner
(
PG motor
)
E4
6
Indoor Unit motor error of
wall mounted air
conditioner
(
DC motor
)
E4
7
Indoor Unit and Outdoor Unit communication
error
E5
(
5E
)
8
Indoor EE Failure
Eb
9
Outdoor Unit DC motor error (3-core terminal
motor)
F0
10
Module protection error
F1
11
PFC protection error
F2
12
Compressor startup error
F3
13
Exhaust sensor error
F4
14
Pressing top head sensor error
F5
15
Outdoor Unit temperature sensor error
F6
16
OVP or UVP error
F7
17
Outdoor Unit main PCB and module panel
communication error
F8
18
Outdoor EE error
F9
19
Recirculated sensor error
(
four-way valve switch
error
)
FA
20
High-pressure protection
P2
21
Liquid Deficiency Protection
P3
Summary of Contents for ASW-H09B5B4/FAR3DI-C3
Page 1: ...AUX Imp Exp Company Limited F Freedom Inverter Split Type Air Conditioner ...
Page 2: ...This manual is for professional maintenance personnel only ...
Page 7: ...4 2 2 Outdoor Unit 1 3P 1 8P 新 2P 2 3P ...
Page 17: ...14 5 Electrical Part 5 1 Wiring Diagram Indoor Unit 09K 12K 18K 24K Outdoor Unit 09K 12K ...
Page 18: ...15 18K 24K ...
Page 19: ...16 Part II Installation and Maintenance 6 Main Tools for Installation and Maintenance ...
Page 71: ...68 Remote Control Can Not Work Trouble shooting procedure ...
Page 72: ...69 9 Exploded Views and Parts List 9 1 Indoor Unit ...
Page 74: ...71 9 2 Outdoor Unit ...
Page 77: ...74 3 Remove air louver 4 Remove air filter 5 Remove Medium frame wiring cover ...
Page 78: ...75 6 Remove medium frame 7 Remove Control the lid 8 Remove Electric box ...
Page 79: ...76 9 Remove press plate 10 Remove component 11 Remove pipe clamp ...
Page 80: ...77 12 Remove evaporator 13 Remove the blade 14 Remove Motor press plate ...
Page 81: ...78 15 Remove Motor 10 2 Outdoor Unit Part Procedure Diagram 1 Outdoor unit ...
Page 82: ...79 2 Remove top cover 3 Remove control box cover ...
Page 83: ...80 4 Remove panel grille 5 Remove front panel ...
Page 84: ...81 6 Remove E part cover 7 Remove right side panel ...
Page 85: ...82 8 Remove axial flow blade 9 Remove outer motor ...
Page 86: ...83 10 Remove electric box assy 11 Remove motor support ...
Page 87: ...84 12 Remove reactor 13 Remove partition board ...
Page 88: ...85 14 Remove left side support plate 15 Remove pipeline assembly ...
Page 89: ...86 16 Remove stop valve assembly 17 Remove valve plate ...