AUX-DC inverter ARV outdoor unit individual series technical manual
114
6.4 Wiring
1. Open electric controlled box cover of indoor unit, wire according to electrical schematic diagram on
electric controlled box cover, firmly press connecting wire on connecting terminal without loosening,
ground wire must be connected at designated position.
2. Open cover plate of electric appliance on right of outdoor unit and wire according to electrical
schematic diagram on backside of electric appliance cover plate.
3. Make sure to thread connecting wire through tension disc and press firmly, wire end must be firmly
pressed on connecting terminal without loosening and ground wire must be connected at designated
position.
4. After wiring, properly bind connecting pipe, connecting wire and drainage pipe with bandage as
shown below:
Note:
1.
Make sure
that unit connecting line can’t be put together with thermal insulation material and should be at
least 20cm away from unit connecting pipe.
2.
Don’t flatten drainpipe when binding
Summary of Contents for ANB66FVAMT