background image

 

RS-325 DUAL STAGE PERIMETER SENSOR 

INSTALLATION / OPERATION MANUAL 

 
 
 
 
The RS-325 uses a microwave frequency to detect field disturbance within a 
contained area. The RS-325 is ideal for detecting a violation into convertibles 
and any open space, which does not have physical protective barriers. The RS-
325 is also effective with conventional vehicles against intrusion or glass 
breakage when a shock sensor fails to trigger. Its unique Pre-Warning circuit can 
detect approach to the vehicle before a break-in actually occurs.  The RS-325 
can be used as a single stage sensor or a dual stage sensor depending on the 
security system to be used with. 
 

The RS-325 is specially designed to work with all Autopage alarms and paging 
systems.  

 
 

M O U N T I N G   P O S I T I O N  

 
 
The position of the RS-325 is critical for its optimum performance. The ultra high 
frequency wave will penetrate carpet, plastic, glass, wood, or fabric; it will not go 
through metals.  The RS-325 can be mounted under a console, under a seat, or 
under carpet. Careful positioning is required to insure that a passenger will not 
step on the RS-325. 
 
 
 

W I R E   C O N N E C T I O N S 

 

 
RED

 = Connect to constant 12 VOLT source. 

BLACK

 = Connect to vehicle GROUND. Please connect this wire to a constant 

stable ground.  * DO NOT USE SWITCHED GROUND FROM SENSOR PLUG* 

GREEN

 = Pre-Warning (-) trigger. Connect to GREEN wire from the AutoPage 

alarm shock sensor port. 

(*)

 

BLUE

 = Main (-) trigger. Connect to BLUE wire from an AutoPage alarm shock 

sensor port. 

(*)

 

 

(*)

 Diodes may be needed to isolate the trigger connection when tied in together with a 

shock sensor. 
 
 
 
 

  

 

AutoPage, Inc. 960 Knox Street unit “B” Torrance, CA 90501 

(310) 618-2002 

 

 

A D J U S T M E N T   A N D   T E S T I N G 

 

1.  External Adjustment 

 
Adjust the EXTERNAL (Pre-Warning) first. This is important and will affect the 
internal sensitivity adjustment. For more sensitivity adjust the Pre-Warning 
potentiometer CLOCKWISE. For less sensitivity adjust the Pre-Warning 
potentiometer COUNTER-CLOCKWISE. The external trigger LED (GREEN) will 
light each time movement is detected within the field. Allow a minimum of five (5) 
seconds between adjustments.  
 
The Pre-Warning will respond with a chirp from the alarm siren each time the 
Pre-Warning field is disturbed. If the disturbance continues, the Pre-Warning will 
chirp the AutoPage alarm siren up to three (3) times within 15 seconds, and 
trigger the alarm immediately after the third chirp. If only one or two disturbances 
takes  place, and is no longer detected, the RS-325 will reset to allow its three 
chirp Pre-Warning feature to continue outside protection.  The reset time is pre-
set by the factory at 4 seconds. 
 

2.  Interior Adjustment 

 
After the external field adjustment is made, adjust the interior potentiometer in 
the same manner until the desired coverage is achieved.  In order to isolate the 
interior coverage for easy adjustment, delete the Pre-Warning of the AutoPage 
alarm by pressing the arming button on the remote within five (5) seconds after 
arming. If the interior protection portion of the RS-325 detects a disturbance, the 
interior LED (RED) will light and the alarm will immediately trigger.  After the 
interior adjustment is completed, check the exterior field again. 
 

NOTE

: If either of the LED’s remains lit after installation, readjust or relocate the 

sensor. 

 

Dual Stage 

Perimeter Sensor 

EXT. 

INT. 

CONNECTO

LED 

LED 

INTERIOR 

EXTERIOR 

RS-325 

 