The RS-32 uses a microwave frequency to detect field disturbance within a 
contained area. The RS-32 is ideal for detecting a violation into convertibles 
and any open space which does not have physical protective barriers. The RS-
32 is also effective with conventional vehicles against intrusion or glass 
breakage when a shock sensor fails to trigger. Its unique Pre-Warning circuit 
can detect approach to the vehicle before a break-in actually occurs.  The RS-
32 can be used as a single stage sensor or a dual stage sensor depending on 
the security system to be used with. 
 

The RS-32 is specially designed to work with the AutoPage alarms and paging 
systems.  

 

NOTE

:  AutoPage systems (RF301, RF501, AP5500) provide a dedicated 

sensor input (PINK) and Pre-Warning input (BLUE/WHITE).  However, only the 
main sensor input (PINK) is available on the AP40000DX.  
 
 
 

M O U N T I N G   P O S I T I O N  

 
 
The position of the RS-32 is critical for its optimum performance. The ultra high 
frequency wave will penetrate carpet, plastic, glass, wood, or fabric; it will not go 
through metals.  The RS-32 can be mounted under a console, under a seat, or 
under carpet. Careful positioning is required to insure that the RS-32 will not be 
stepped on by a passenger. 
 
 
 

W I R E   C O N N E C T I O N S 

 

 
RED

 = Connect to constant 12 VOLT source. 

BLACK

 = Connect to vehicle GROUND. 

PINK

 = Main unit trigger. Connect to PINK from an AutoPage alarm. 

BLUE

 = Pre-Warning trigger. Connect to BLUE/WHITE from an AutoPage alarm 

(optional). 
 
 

NOTE

: When used with other accessories (e.g., shock sensor) or switches that 

share the same negative input of the alarm, an isolation diode (IN4001) must 

be added to protect the RS-32. If used with an AutoPage SIS-3, we recommend 
two diodes be added to protect both sensors. 

 
 

  

 

AutoPage, Inc. 1815 W. 205th Street, Suite 101, Torrance, CA 90501 

(310) 618-2002 

 

 

A D J U S T M E N T   A N D   T E S T I N G 

 

1.  External Adjustment 

 
Adjust the EXTERNAL (Pre-Warning) first. This is important and will affect the 
internal sensitivity adjustment. For more sensitivity adjust the Pre-Warning 
potentiometer CLOCKWISE. For less sensitivity adjust the Pre-Warning 
potentiometer COUNTER-CLOCKWISE. The external trigger LED (GREEN)  will 
light each time movement is detected within the field. Allow a minimum of five 
(5) seconds between adjustments.  
 
The Pre-Warning will respond with a chirp from the alarm siren each time the 
Pre-Warning field is disturbed. If the disturbance continues, the Pre-Warning 
will chirp the AutoPage alarm siren up to three (3) times within 15 seconds, 
and trigger the alarm immediately after the third chirp. If only one or two 
disturbances takes place, and is no longer detected, the RS-32 will reset to 
allow its three chirp Pre-Warning feature to continue outside protection.  The 
reset time is pre-set by the factory at 4 seconds. 
 