Autool LM 706 Manual Download Page 10

LM 706 A/C Service Station

7

Note: in order to ensure the normal operation of the filling function, the
reserved amount of refrigerant in the equipment tank is set to 1kg, and the
setting value of the filling amount is: the amount of refrigerant in the tank
minus 1kg. For example, if the refrigerant quantity in the tank is 1.2kg, the
maximum setting value of filling quantity is 1.2-1 = 0.2kg.

C

Note: In the recharging process, if shows the menu, it means that you need to turn on

the car air-conditioning to complete the recharging process. Later, you should supply
new refrigerant into the tank.

3.9

Auto. Mode

A

Under this mode, all of the functions can be run full automatically after setting the
parameters.

B

Before running, must empty the used oil bottle entirely and fill enough new oil into the new
bottle.

C

Operations:

D

Select Auto. Mode function and set parameter.

E

The parameter setting method is the same as the single function setting method mentioned
above.

F

If it displays code as W** during the process, please deal with it according to prompt
information.

3.10

Database

A

Here you can read the refrigerant type and filling amount and the refrigerant oil type and
filling amount of the automotive.

B

Operations:

Summary of Contents for LM 706

Page 1: ...LM 706 A C Service Station LM 706 A C Service Station...

Page 2: ...ts such as cooling fans alternators and heating components etc to avoid harm Wear protective clothing gloves and goggles As automotive air conditioning pipe flushing the operator must be fully familia...

Page 3: ...3 6 Vacuum 5 3 7 Fill new oil 5 3 8 Recharging 6 3 9 Auto Mode 7 3 10 Database 7 3 11 Auxiliary functions 8 3 11 1 Usage of the Auxiliary Port 8 3 11 2 System functions 8 3 11 2 1 Parameter setting 8...

Page 4: ...with the gas or the liquid C Touch button improved control performance long service life D Designed with large size LCD E Database F USB update port program and database can be updated G Equipped with...

Page 5: ...Vacuum C Fill new oil D Recharging E Auto Mode 2 2 Subsidiary functions A Database B Parameter setting C Calibration professional D Supply main tank E Maintenance procedures dry filter exchange vacuu...

Page 6: ...Open the back door take out all the fillers on both sides of the cylinder and under the scale pan so that the scale pan is suspended B Set language select and press OK HP gauge Operation panel LP gau...

Page 7: ...gerants at least 2kg F Please read this user manual carefully before operating 3 3 Preparations before Operation A Connect the red blue couplers to the HP LP ports of automobile air conditioner respec...

Page 8: ...or with the front and rear wind C Operations Note after the operation of the equipment there is no need for personnel to take care of it until it is finished by itself D If it displays code as W durin...

Page 9: ...the equipment stops automatically Note in the process of new oil filling do not take the oil bottle and shake the equipment otherwise it will lead to inaccurate filling 3 8 Recharging Through this fu...

Page 10: ...plete the recharging process Later you should supply new refrigerant into the tank 3 9 Auto Mode A Under this mode all of the functions can be run full automatically after setting the parameters B Bef...

Page 11: ...back the cap to the auxiliary port Tip when using the external tank to fill the refrigerant it may be necessary to start the car and turn on the air conditioner in some cases It is forbidden to conne...

Page 12: ...igerant of the equipment is less than 2kg it need to be supplemented If the refrigerant is less than 1kg the filling function will not be performed B Operations B 1 Select Supply main tank function B...

Page 13: ...ollowed by letter SN D Please attention the mounting direction of the dry filter 3 11 2 5 Drain used oil Normally the equipment will automatically drain the used oil after flushing and or recovery fun...

Page 14: ...ry System inquiry you can query the equipment usage Servicer info inquire about the phone number of the service provider Equipment infor query equipment serial number software and hardware version and...

Page 15: ...l clean and ventilated place h The maintenance items indicated by the equipment should be done in time i When the equipment is not in use for a long time or when it is loaded and transferred to anothe...

Reviews: